BRLR
Recessed LED Retrofit Kit

Upgrade your existing 2x2, 1x4, or 2x4 recessed troffers with the BRLR LED retrofit kit for up to 50% energy savings and enhanced performance with simple installation.

Product Overview

Features

  • Operating temperature ranges available from -20C to 25C
  • L70 of 110,000+ hours, L90 of 34,000+ hours
  • Standard 0 - 10V dimming
  • Available in 2700K, 3000K, 3500K, 4000K, 5000K and 6500K
  • Lumen packages are available ranging from 2L (2071lm) to 6L (6064lm)

Construction

  • Manufactured in Ontario, Canada
  • Powder-coated in high reflectance gloss white (other colours available)
  • Manufactured from pre-painted white steel
  • Precision bent for added strength and rigidity
  • Shallow design for ease of installation and a clean, professional look

Approvals

  • ETL certified to UL Canada and United States standards
  • Made with UL Listed components
  • DLC Listed

Electrical

  • Available in 120-277V, 120-347V, 347V and 480V

Options

  • 90 and 95+ CRI Options Available
  • 120-347V(UN3) Available
Files and Resources
Wattage Tables

BRLR, 1x4 Wattage Table

Length Lumen Output Actual Lumen Output Fixture Wattage Lumens per Watt
1x4 2.00 2120 17.52 121.00
1x4 2.50 2634 21.70 121.40
1x4 3.00 3147 25.87 121.70
1x4 3.50 3661 30.05 121.90
1x4 4.00 4130 35.80 115.40

BRLR, 2x2 Wattage Table

Length Lumen Output Actual Lumen Output Fixture Wattage Lumens per Watt
2x2 2.00 2071 17.45 118.70
2x2 2.50 2573 21.61 119.80
2x2 3.00 3075 25.77 119.30
2x2 3.50 3577 29.93 119.50
2x2 4.00 4079 34.08 119.70

BRLR, 2x4 Wattage Table

Length Lumen Output Actual Lumen Output Fixture Wattage Lumens per Watt
2x4 4.00 4384 34.03 128.90
2x4 4.50 4804 37.71 127.40
2x4 5.00 5224 41.38 126.30
2x4 5.50 5644 45.06 125.30
2x4 6.00 6064 48.74 124.40
Photometry

BRLR-24-10L-840 - Cone of Light & Candela Polar Plot

Mtg Height Light Level Beam Diameter
6.0 ft 98.0 fc 14.0 ft
8.0 ft 55.1 fc 18.6 ft
10.0 ft 35.3 fc 23.3 ft
12.0 ft 24.5 fc 28.0 ft
14.0 ft 18.0 fc 32.6 ft
16.0 ft 13.8 fc 37.3 ft
BRLR Photometry, candela polar plot luminaire testing data